ResMed Core Implementation Guide
0.37.0 - ci-build International flag

ResMed Core Implementation Guide - Local Development build (v0.37.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions

Resource Profile: ResMed Device

Official URL: http://resmed.com/fhir/core/StructureDefinition/resmed-device Version: 0.37.0
Draft as of 2024-01-11 Computable Name: ResMedDevice

Minimalist resource profile for ResMed devices, sufficient for capturing key details

Usage:

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from Device

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device Device
... Slices for extension 1..*ExtensionExtension
Slice: Unordered, Open by value:url
... verificationCode 1..1stringExtension
URL: http://resmed.com/fhir/core/StructureDefinition/ResMedSerialNumberVerificationCode
... Slices for identifier 1..*IdentifierInstance identifier
Slice: Unordered, Open by pattern:system
.... identifier:SERIAL 1..1IdentifierInstance identifier
..... system 1..1uriThe namespace for the identifier value
Required Pattern: http://identifier.resmed.com/device-serial
..... value 1..1stringThe value that is unique
... manufacturer 1..1stringName of device manufacturer
Required Pattern: ResMed Ltd
... serialNumber 1..1stringSerial number assigned by the manufacturer
... deviceName 1..*BackboneElementThe name of the device as given by the manufacturer
... modelNumber 1..1stringThe model number for the device
... type 1..1CodeableConceptThe kind or type of device
Binding: ResMed device type codes (required)
... Slices for version 3..*BackboneElementThe actual design of the device or software version running on the device
Slice: Unordered, Open by pattern:type
.... version:ResMedVID S1..1BackboneElementThe actual design of the device or software version running on the device
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: variant-identifier
.... version:ResMedMID S1..1BackboneElementThe actual design of the device or software version running on the device
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: metadata-identifier
.... version:ResMedSoftware S1..1BackboneElementThe actual design of the device or software version running on the device
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: application-identifier

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSet
Device.typerequiredResMedDeviceTypeValueSet (a valid code from ResMed device type CodeSystem)
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..*DeviceItem used in healthcare
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... Slices for extension 1..*ExtensionExtension
Slice: Unordered, Open by value:url
... verificationCode 1..1stringExtension
URL: http://resmed.com/fhir/core/StructureDefinition/ResMedSerialNumberVerificationCode
... Slices for identifier 1..*IdentifierInstance identifier
Slice: Unordered, Open by pattern:system
.... identifier:SERIAL 1..1IdentifierInstance identifier
..... use ?!Σ0..1codeusual | official | temp | secondary | old (If known)
Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known .

..... system Σ1..1uriThe namespace for the identifier value
Required Pattern: http://identifier.resmed.com/device-serial
..... value Σ1..1stringThe value that is unique
Example General: 123456
... status ?!Σ1..1codeactive | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... manufacturer 1..1stringName of device manufacturer
Required Pattern: ResMed Ltd
... serialNumber 1..1stringSerial number assigned by the manufacturer
... deviceName 1..*BackboneElementThe name of the device as given by the manufacturer
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... name 1..1stringThe name of the device
.... type 1..1codeudi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... modelNumber 1..1stringThe model number for the device
... type 1..1CodeableConceptThe kind or type of device
Binding: ResMed device type codes (required)
... Slices for version 3..*BackboneElementThe actual design of the device or software version running on the device
Slice: Unordered, Open by pattern:type
.... version:All Slices Content/Rules for all slices
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... value 1..1stringThe version text
.... version:ResMedVID S1..1BackboneElementThe actual design of the device or software version running on the device
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: variant-identifier
..... value 1..1stringThe version text
.... version:ResMedMID S1..1BackboneElementThe actual design of the device or software version running on the device
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: metadata-identifier
..... value 1..1stringThe version text
.... version:ResMedSoftware S1..1BackboneElementThe actual design of the device or software version running on the device
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: application-identifier
..... value 1..1stringThe version text

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet
Device.identifier:SERIAL.userequiredIdentifierUse
Device.statusrequiredFHIRDeviceStatus
Device.deviceName.typerequiredDeviceNameType
Device.typerequiredResMedDeviceTypeValueSet (a valid code from ResMed device type CodeSystem)

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..*DeviceItem used in healthcare
... id Σ0..1idLogical id of this artifact
... meta Σ0..1MetaMetadata about the resource
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguagesMax Binding
... text 0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... Slices for extension 1..*ExtensionExtension
Slice: Unordered, Open by value:url
... verificationCode 1..1stringExtension
URL: http://resmed.com/fhir/core/StructureDefinition/ResMedSerialNumberVerificationCode
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... Slices for identifier 1..*IdentifierInstance identifier
Slice: Unordered, Open by pattern:system
.... identifier:SERIAL 1..1IdentifierInstance identifier
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
..... use ?!Σ0..1codeusual | official | temp | secondary | old (If known)
Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known .

..... type Σ0..1CodeableConceptDescription of identifier
Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose.

..... system Σ1..1uriThe namespace for the identifier value
Required Pattern: http://identifier.resmed.com/device-serial
..... value Σ1..1stringThe value that is unique
Example General: 123456
..... period Σ0..1PeriodTime period when id is/was valid for use
..... assigner Σ0..1Reference(Organization)Organization that issued id (may be just text)
... definition 0..1Reference(DeviceDefinition)The reference to the definition for the device
... udiCarrier Σ0..*BackboneElementUnique Device Identifier (UDI) Barcode string
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... deviceIdentifier Σ0..1stringMandatory fixed portion of UDI
.... issuer 0..1uriUDI Issuing Organization
.... jurisdiction 0..1uriRegional UDI authority
.... carrierAIDC Σ0..1base64BinaryUDI Machine Readable Barcode String
.... carrierHRF Σ0..1stringUDI Human Readable Barcode String
.... entryType 0..1codebarcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.

... status ?!Σ1..1codeactive | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... statusReason 0..*CodeableConceptonline | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.


... distinctIdentifier 0..1stringThe distinct identification string
... manufacturer 1..1stringName of device manufacturer
Required Pattern: ResMed Ltd
... manufactureDate 0..1dateTimeDate when the device was made
... expirationDate 0..1dateTimeDate and time of expiry of this device (if applicable)
... lotNumber 0..1stringLot number of manufacture
... serialNumber 1..1stringSerial number assigned by the manufacturer
... deviceName 1..*BackboneElementThe name of the device as given by the manufacturer
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... name 1..1stringThe name of the device
.... type 1..1codeudi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... modelNumber 1..1stringThe model number for the device
... partNumber 0..1stringThe part number of the device
... type 1..1CodeableConceptThe kind or type of device
Binding: ResMed device type codes (required)
... specialization 0..*BackboneElementThe capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... systemType 1..1CodeableConceptThe standard that is used to operate and communicate
.... version 0..1stringThe version of the standard that is used to operate and communicate
... Slices for version 3..*BackboneElementThe actual design of the device or software version running on the device
Slice: Unordered, Open by pattern:type
.... version:All Slices Content/Rules for all slices
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 0..1CodeableConceptThe type of the device version
..... component 0..1IdentifierA single component of the device version
..... value 1..1stringThe version text
.... version:ResMedVID S1..1BackboneElementThe actual design of the device or software version running on the device
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... id0..1stringUnique id for inter-element referencing
...... extension0..*ExtensionAdditional content defined by implementations
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... id0..1stringUnique id for inter-element referencing
....... extension0..*ExtensionAdditional content defined by implementations
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... version0..1stringVersion of the system - if relevant
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: variant-identifier
....... display0..1stringRepresentation defined by the system
....... userSelected0..1booleanIf this coding was chosen directly by the user
...... text0..1stringPlain text representation of the concept
..... component 0..1IdentifierA single component of the device version
..... value 1..1stringThe version text
.... version:ResMedMID S1..1BackboneElementThe actual design of the device or software version running on the device
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... id0..1stringUnique id for inter-element referencing
...... extension0..*ExtensionAdditional content defined by implementations
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... id0..1stringUnique id for inter-element referencing
....... extension0..*ExtensionAdditional content defined by implementations
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... version0..1stringVersion of the system - if relevant
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: metadata-identifier
....... display0..1stringRepresentation defined by the system
....... userSelected0..1booleanIf this coding was chosen directly by the user
...... text0..1stringPlain text representation of the concept
..... component 0..1IdentifierA single component of the device version
..... value 1..1stringThe version text
.... version:ResMedSoftware S1..1BackboneElementThe actual design of the device or software version running on the device
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... id0..1stringUnique id for inter-element referencing
...... extension0..*ExtensionAdditional content defined by implementations
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... id0..1stringUnique id for inter-element referencing
....... extension0..*ExtensionAdditional content defined by implementations
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... version0..1stringVersion of the system - if relevant
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: application-identifier
....... display0..1stringRepresentation defined by the system
....... userSelected0..1booleanIf this coding was chosen directly by the user
...... text0..1stringPlain text representation of the concept
..... component 0..1IdentifierA single component of the device version
..... value 1..1stringThe version text
... property 0..*BackboneElementThe actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... type 1..1CodeableConceptCode that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..*QuantityProperty value as a quantity
.... valueCode 0..*CodeableConceptProperty value as a code, e.g., NTP4 (synced to NTP)
... patient 0..1Reference(Patient)Patient to whom Device is affixed
... owner 0..1Reference(Organization)Organization responsible for device
... contact 0..*ContactPointDetails for human/organization for support
... location 0..1Reference(Location)Where the device is found
... url 0..1uriNetwork address to contact device
... note 0..*AnnotationDevice notes and comments
... safety Σ0..*CodeableConceptSafety Characteristics of Device
... parent 0..1Reference(Device)The parent device

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet
Device.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
Device.identifier:SERIAL.userequiredIdentifierUse
Device.identifier:SERIAL.typeextensibleIdentifier Type Codes
Device.udiCarrier.entryTyperequiredUDIEntryType
Device.statusrequiredFHIRDeviceStatus
Device.statusReasonextensibleFHIRDeviceStatusReason
Device.deviceName.typerequiredDeviceNameType
Device.typerequiredResMedDeviceTypeValueSet (a valid code from ResMed device type CodeSystem)

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

This structure is derived from Device

Summary

Mandatory: 18 elements
Must-Support: 3 elements

Extensions

This structure refers to these extensions:

Slices

This structure defines the following Slices:

  • The element Device.identifier is sliced based on the value of pattern:system
  • The element Device.version is sliced based on the value of pattern:type

Differential View

This structure is derived from Device

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device Device
... Slices for extension 1..*ExtensionExtension
Slice: Unordered, Open by value:url
... verificationCode 1..1stringExtension
URL: http://resmed.com/fhir/core/StructureDefinition/ResMedSerialNumberVerificationCode
... Slices for identifier 1..*IdentifierInstance identifier
Slice: Unordered, Open by pattern:system
.... identifier:SERIAL 1..1IdentifierInstance identifier
..... system 1..1uriThe namespace for the identifier value
Required Pattern: http://identifier.resmed.com/device-serial
..... value 1..1stringThe value that is unique
... manufacturer 1..1stringName of device manufacturer
Required Pattern: ResMed Ltd
... serialNumber 1..1stringSerial number assigned by the manufacturer
... deviceName 1..*BackboneElementThe name of the device as given by the manufacturer
... modelNumber 1..1stringThe model number for the device
... type 1..1CodeableConceptThe kind or type of device
Binding: ResMed device type codes (required)
... Slices for version 3..*BackboneElementThe actual design of the device or software version running on the device
Slice: Unordered, Open by pattern:type
.... version:ResMedVID S1..1BackboneElementThe actual design of the device or software version running on the device
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: variant-identifier
.... version:ResMedMID S1..1BackboneElementThe actual design of the device or software version running on the device
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: metadata-identifier
.... version:ResMedSoftware S1..1BackboneElementThe actual design of the device or software version running on the device
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: application-identifier

doco Documentation for this format

Terminology Bindings (Differential)

PathConformanceValueSet
Device.typerequiredResMedDeviceTypeValueSet (a valid code from ResMed device type CodeSystem)

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..*DeviceItem used in healthcare
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... Slices for extension 1..*ExtensionExtension
Slice: Unordered, Open by value:url
... verificationCode 1..1stringExtension
URL: http://resmed.com/fhir/core/StructureDefinition/ResMedSerialNumberVerificationCode
... Slices for identifier 1..*IdentifierInstance identifier
Slice: Unordered, Open by pattern:system
.... identifier:SERIAL 1..1IdentifierInstance identifier
..... use ?!Σ0..1codeusual | official | temp | secondary | old (If known)
Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known .

..... system Σ1..1uriThe namespace for the identifier value
Required Pattern: http://identifier.resmed.com/device-serial
..... value Σ1..1stringThe value that is unique
Example General: 123456
... status ?!Σ1..1codeactive | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... manufacturer 1..1stringName of device manufacturer
Required Pattern: ResMed Ltd
... serialNumber 1..1stringSerial number assigned by the manufacturer
... deviceName 1..*BackboneElementThe name of the device as given by the manufacturer
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... name 1..1stringThe name of the device
.... type 1..1codeudi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... modelNumber 1..1stringThe model number for the device
... type 1..1CodeableConceptThe kind or type of device
Binding: ResMed device type codes (required)
... Slices for version 3..*BackboneElementThe actual design of the device or software version running on the device
Slice: Unordered, Open by pattern:type
.... version:All Slices Content/Rules for all slices
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... value 1..1stringThe version text
.... version:ResMedVID S1..1BackboneElementThe actual design of the device or software version running on the device
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: variant-identifier
..... value 1..1stringThe version text
.... version:ResMedMID S1..1BackboneElementThe actual design of the device or software version running on the device
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: metadata-identifier
..... value 1..1stringThe version text
.... version:ResMedSoftware S1..1BackboneElementThe actual design of the device or software version running on the device
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: application-identifier
..... value 1..1stringThe version text

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet
Device.identifier:SERIAL.userequiredIdentifierUse
Device.statusrequiredFHIRDeviceStatus
Device.deviceName.typerequiredDeviceNameType
Device.typerequiredResMedDeviceTypeValueSet (a valid code from ResMed device type CodeSystem)

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Device 0..*DeviceItem used in healthcare
... id Σ0..1idLogical id of this artifact
... meta Σ0..1MetaMetadata about the resource
... implicitRules ?!Σ0..1uriA set of rules under which this content was created
... language 0..1codeLanguage of the resource content
Binding: CommonLanguages (preferred): A human language.

Additional BindingsPurpose
AllLanguagesMax Binding
... text 0..1NarrativeText summary of the resource, for human interpretation
... contained 0..*ResourceContained, inline Resources
... Slices for extension 1..*ExtensionExtension
Slice: Unordered, Open by value:url
... verificationCode 1..1stringExtension
URL: http://resmed.com/fhir/core/StructureDefinition/ResMedSerialNumberVerificationCode
... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
... Slices for identifier 1..*IdentifierInstance identifier
Slice: Unordered, Open by pattern:system
.... identifier:SERIAL 1..1IdentifierInstance identifier
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
Slice: Unordered, Open by value:url
..... use ?!Σ0..1codeusual | official | temp | secondary | old (If known)
Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known .

..... type Σ0..1CodeableConceptDescription of identifier
Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose.

..... system Σ1..1uriThe namespace for the identifier value
Required Pattern: http://identifier.resmed.com/device-serial
..... value Σ1..1stringThe value that is unique
Example General: 123456
..... period Σ0..1PeriodTime period when id is/was valid for use
..... assigner Σ0..1Reference(Organization)Organization that issued id (may be just text)
... definition 0..1Reference(DeviceDefinition)The reference to the definition for the device
... udiCarrier Σ0..*BackboneElementUnique Device Identifier (UDI) Barcode string
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... deviceIdentifier Σ0..1stringMandatory fixed portion of UDI
.... issuer 0..1uriUDI Issuing Organization
.... jurisdiction 0..1uriRegional UDI authority
.... carrierAIDC Σ0..1base64BinaryUDI Machine Readable Barcode String
.... carrierHRF Σ0..1stringUDI Human Readable Barcode String
.... entryType 0..1codebarcode | rfid | manual +
Binding: UDIEntryType (required): Codes to identify how UDI data was entered.

... status ?!Σ1..1codeactive | inactive | entered-in-error | unknown
Binding: FHIRDeviceStatus (required): The availability status of the device.

... statusReason 0..*CodeableConceptonline | paused | standby | offline | not-ready | transduc-discon | hw-discon | off
Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device.


... distinctIdentifier 0..1stringThe distinct identification string
... manufacturer 1..1stringName of device manufacturer
Required Pattern: ResMed Ltd
... manufactureDate 0..1dateTimeDate when the device was made
... expirationDate 0..1dateTimeDate and time of expiry of this device (if applicable)
... lotNumber 0..1stringLot number of manufacture
... serialNumber 1..1stringSerial number assigned by the manufacturer
... deviceName 1..*BackboneElementThe name of the device as given by the manufacturer
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... name 1..1stringThe name of the device
.... type 1..1codeudi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other
Binding: DeviceNameType (required): The type of name the device is referred by.

... modelNumber 1..1stringThe model number for the device
... partNumber 0..1stringThe part number of the device
... type 1..1CodeableConceptThe kind or type of device
Binding: ResMed device type codes (required)
... specialization 0..*BackboneElementThe capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... systemType 1..1CodeableConceptThe standard that is used to operate and communicate
.... version 0..1stringThe version of the standard that is used to operate and communicate
... Slices for version 3..*BackboneElementThe actual design of the device or software version running on the device
Slice: Unordered, Open by pattern:type
.... version:All Slices Content/Rules for all slices
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 0..1CodeableConceptThe type of the device version
..... component 0..1IdentifierA single component of the device version
..... value 1..1stringThe version text
.... version:ResMedVID S1..1BackboneElementThe actual design of the device or software version running on the device
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... id0..1stringUnique id for inter-element referencing
...... extension0..*ExtensionAdditional content defined by implementations
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... id0..1stringUnique id for inter-element referencing
....... extension0..*ExtensionAdditional content defined by implementations
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... version0..1stringVersion of the system - if relevant
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: variant-identifier
....... display0..1stringRepresentation defined by the system
....... userSelected0..1booleanIf this coding was chosen directly by the user
...... text0..1stringPlain text representation of the concept
..... component 0..1IdentifierA single component of the device version
..... value 1..1stringThe version text
.... version:ResMedMID S1..1BackboneElementThe actual design of the device or software version running on the device
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... id0..1stringUnique id for inter-element referencing
...... extension0..*ExtensionAdditional content defined by implementations
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... id0..1stringUnique id for inter-element referencing
....... extension0..*ExtensionAdditional content defined by implementations
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... version0..1stringVersion of the system - if relevant
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: metadata-identifier
....... display0..1stringRepresentation defined by the system
....... userSelected0..1booleanIf this coding was chosen directly by the user
...... text0..1stringPlain text representation of the concept
..... component 0..1IdentifierA single component of the device version
..... value 1..1stringThe version text
.... version:ResMedSoftware S1..1BackboneElementThe actual design of the device or software version running on the device
..... id 0..1stringUnique id for inter-element referencing
..... extension 0..*ExtensionAdditional content defined by implementations
..... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
..... type 1..1CodeableConceptThe type of the device version
Required Pattern: At least the following
...... id0..1stringUnique id for inter-element referencing
...... extension0..*ExtensionAdditional content defined by implementations
...... coding1..*CodingCode defined by a terminology system
Fixed Value: (complex)
....... id0..1stringUnique id for inter-element referencing
....... extension0..*ExtensionAdditional content defined by implementations
....... system1..1uriIdentity of the terminology system
Fixed Value: http://terminology.resmed.com/CodeSystem/device-version-components
....... version0..1stringVersion of the system - if relevant
....... code1..1codeSymbol in syntax defined by the system
Fixed Value: application-identifier
....... display0..1stringRepresentation defined by the system
....... userSelected0..1booleanIf this coding was chosen directly by the user
...... text0..1stringPlain text representation of the concept
..... component 0..1IdentifierA single component of the device version
..... value 1..1stringThe version text
... property 0..*BackboneElementThe actual configuration settings of a device as it actually operates, e.g., regulation status, time properties
.... id 0..1stringUnique id for inter-element referencing
.... extension 0..*ExtensionAdditional content defined by implementations
.... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
.... type 1..1CodeableConceptCode that specifies the property DeviceDefinitionPropetyCode (Extensible)
.... valueQuantity 0..*QuantityProperty value as a quantity
.... valueCode 0..*CodeableConceptProperty value as a code, e.g., NTP4 (synced to NTP)
... patient 0..1Reference(Patient)Patient to whom Device is affixed
... owner 0..1Reference(Organization)Organization responsible for device
... contact 0..*ContactPointDetails for human/organization for support
... location 0..1Reference(Location)Where the device is found
... url 0..1uriNetwork address to contact device
... note 0..*AnnotationDevice notes and comments
... safety Σ0..*CodeableConceptSafety Characteristics of Device
... parent 0..1Reference(Device)The parent device

doco Documentation for this format

Terminology Bindings

PathConformanceValueSet
Device.languagepreferredCommonLanguages
Additional Bindings Purpose
AllLanguages Max Binding
Device.identifier:SERIAL.userequiredIdentifierUse
Device.identifier:SERIAL.typeextensibleIdentifier Type Codes
Device.udiCarrier.entryTyperequiredUDIEntryType
Device.statusrequiredFHIRDeviceStatus
Device.statusReasonextensibleFHIRDeviceStatusReason
Device.deviceName.typerequiredDeviceNameType
Device.typerequiredResMedDeviceTypeValueSet (a valid code from ResMed device type CodeSystem)

Constraints

IdGradePath(s)DetailsRequirements
dom-2errorDeviceIf the resource is contained in another resource, it SHALL NOT contain nested Resources
: contained.contained.empty()
dom-3errorDeviceIf the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource
: contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty()
dom-4errorDeviceIf a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated
: contained.meta.versionId.empty() and contained.meta.lastUpdated.empty()
dom-5errorDeviceIf a resource is contained in another resource, it SHALL NOT have a security label
: contained.meta.security.empty()
dom-6best practiceDeviceA resource should have narrative for robust management
: text.`div`.exists()
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()

This structure is derived from Device

Summary

Mandatory: 18 elements
Must-Support: 3 elements

Extensions

This structure refers to these extensions:

Slices

This structure defines the following Slices:

  • The element Device.identifier is sliced based on the value of pattern:system
  • The element Device.version is sliced based on the value of pattern:type

 

Other representations of profile: CSV, Excel, Schematron