ResMed Core Implementation Guide
0.37.0 - ci-build
ResMed Core Implementation Guide - Local Development build (v0.37.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Draft as of 2024-01-11 |
<CodeSystem xmlns="http://hl7.org/fhir">
<id value="resmed-device-type-code-system"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p>This case-sensitive code system <code>http://terminology.resmed.com/CodeSystem/device-type</code> defines the following codes:</p><table class="codes"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td style="white-space:nowrap">cpap-device<a name="resmed-device-type-code-system-cpap-device"> </a></td><td>Continuous positive airway pressure device</td></tr><tr><td style="white-space:nowrap">hft-device<a name="resmed-device-type-code-system-hft-device"> </a></td><td>High flow therapy device</td></tr><tr><td style="white-space:nowrap">non-invasive-ventilator<a name="resmed-device-type-code-system-non-invasive-ventilator"> </a></td><td>Non-invasive ventilator for respiratory insufficiency</td></tr><tr><td style="white-space:nowrap">ventilator<a name="resmed-device-type-code-system-ventilator"> </a></td><td>Invasive and non-invasive ventilator for respiratory failure</td></tr></table></div>
</text>
<url value="http://terminology.resmed.com/CodeSystem/device-type"/>
<version value="0.37.0"/>
<name value="ResMedDeviceTypeCodeSystem"/>
<title value="ResMed device type CodeSystem"/>
<status value="draft"/>
<experimental value="false"/>
<date value="2024-01-11T18:32:48+00:00"/>
<publisher value="ResMed Corp"/>
<contact>
<name value="ResMed Corp"/>
<telecom>
<system value="url"/>
<value value="https://www.resmed.com"/>
</telecom>
<telecom>
<system value="email"/>
<value value="atomteam-halifax@resmed.com"/>
</telecom>
</contact>
<description value="ResMed device type CodeSystem"/>
<jurisdiction>
<coding>
<system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
<code value="001"/>
</coding>
</jurisdiction>
<caseSensitive value="true"/>
<content value="complete"/>
<count value="4"/>
<concept>
<code value="cpap-device"/>
<display value="Continuous positive airway pressure device"/>
</concept>
<concept>
<code value="hft-device"/>
<display value="High flow therapy device"/>
</concept>
<concept>
<code value="non-invasive-ventilator"/>
<display value="Non-invasive ventilator for respiratory insufficiency"/>
</concept>
<concept>
<code value="ventilator"/>
<display
value="Invasive and non-invasive ventilator for respiratory failure"/>
</concept>