Bundle astral-settings-bundle of type transaction
Entry 1 - fullUrl = http://example.org/fhir/Observation/astral-spont-settings-observation
Request:
POST Observation
Resource Observation:
Generated Narrative: Observation
Resource Observation "astral-spont-settings-observation"
Profile: ResMed Device Settings Observation
ResMedReceivedDateTime: May 7, 2021, 6:28:17 PM
status: PRELIMINARY
code: Parent observation for device therapy settings, as reported by the device (ResMed observation CodeSystem#therapy-settings)
subject: Device/astral
effective: 2021-05-07
issued: May 7, 2021, 6:28:17 PM
hasMember:
status: PRELIMINARY
code: apnea-breath-type (ResMed Observation Metrics CodeSystem#apnea-breath-type)
value: No spont breath (ResMed settings values for spont breath#NOSPONTBREATH)
device: Device/astral
status: PRELIMINARY
code: apnea-interval (ResMed Observation Metrics CodeSystem#apnea-interval)
value: 262
device: Device/astral
status: PRELIMINARY
code: apnea-response-type (ResMed Observation Metrics CodeSystem#apnea-response-type)
value: PACV alarm (ResMed settings values for apnea response#PACVALARM)
device: Device/astral
status: PRELIMINARY
code: set-frequency-apnea-vent (ResMed Respiratory Setting CodeSystem#set-frequency-apnea-vent)
value: 30
device: Device/astral
status: PRELIMINARY
code: set-peak-inspiratory-flow-apnea-vent (ResMed Respiratory Setting CodeSystem#set-peak-inspiratory-flow-apnea-vent)
value: 73
device: Device/astral
status: PRELIMINARY
code: set-pressure-assist-apnea-vent (ResMed Respiratory Setting CodeSystem#set-pressure-assist-apnea-vent)
value: 20.6
device: Device/astral
status: PRELIMINARY
code: set-inspiratory-time-apnea-vent (ResMed Respiratory Setting CodeSystem#set-inspiratory-time-apnea-vent)
value: 1.3
device: Device/astral
status: PRELIMINARY
code: set-tidal-volume-apnea-vent (ResMed Respiratory Setting CodeSystem#set-tidal-volume-apnea-vent)
value: 1.045
device: Device/astral
status: PRELIMINARY
code: auto-expiratory-pressure-state (ResMed Respiratory Setting CodeSystem#auto-expiratory-pressure-state)
value: Off (ResMed settings values for enable/disable options#OFF)
device: Device/astral
status: PRELIMINARY
code: patient-circuit-type (ResMed Observation Metrics CodeSystem#patient-circuit-type)
value: Single circuit with leak (vented) (ResMed Ventilator Circuit CodeSystem#single-with-leak)
device: Device/astral
status: PRELIMINARY
code: cycle-threshold (ResMed Observation Metrics CodeSystem#cycle-threshold)
value: 50
device: Device/astral
status: PRELIMINARY
code: target-expiratory-pressure (ResMed Observation Metrics CodeSystem#target-expiratory-pressure)
value: 15
device: Device/astral
status: PRELIMINARY
code: patient-height (ResMed Observation Metrics CodeSystem#patient-height)
value: 200 cm (Details: UCUM code cm = 'cm')
device: Device/astral
status: PRELIMINARY
code: patient-interface (ResMed Observation Metrics CodeSystem#patient-interface)
value: Mask (ResMed settings values for interface type#MASK)
device: Device/astral
status: PRELIMINARY
code: mask-type (ResMed Observation Metrics CodeSystem#mask-type)
value: InLineVent (ResMed settings values for mask type#INLINEVENT)
device: Device/astral
status: PRELIMINARY
code: max-expiratory-pressure (ResMed Observation Metrics CodeSystem#max-expiratory-pressure)
value: 22.2
device: Device/astral
status: PRELIMINARY
code: min-expiratory-pressure (ResMed Observation Metrics CodeSystem#min-expiratory-pressure)
value: 20.8
device: Device/astral
status: PRELIMINARY
code: patient-type (ResMed Observation Metrics CodeSystem#patient-type)
value: Adult (ResMed settings values for patient type#ADULT)
device: Device/astral
status: PRELIMINARY
code: rise-time (ResMed Observation Metrics CodeSystem#rise-time)
value: 0.5
device: Device/astral
status: PRELIMINARY
code: target-alveolar-ventilation (ResMed Observation Metrics CodeSystem#target-alveolar-ventilation)
value: 10
device: Device/astral
status: PRELIMINARY
code: target-respiratory-rate (ResMed Observation Metrics CodeSystem#target-respiratory-rate)
value: 15
device: Device/astral
status: PRELIMINARY
code: set-max-inspiratory-time (ResMed Observation Metrics CodeSystem#set-max-inspiratory-time)
value: 2
device: Device/astral
status: PRELIMINARY
code: set-min-inspiratory-time (ResMed Observation Metrics CodeSystem#set-min-inspiratory-time)
value: 3
device: Device/astral
status: PRELIMINARY
code: trigger-type (ResMed Observation Metrics CodeSystem#trigger-type)
value: OFF (ResMed settings values for levels#OFF)
device: Device/astral
status: PRELIMINARY
code: max-pressure-support (ResMed Observation Metrics CodeSystem#max-pressure-support)
value: 25
device: Device/astral
status: PRELIMINARY
code: min-pressure-support (ResMed Observation Metrics CodeSystem#min-pressure-support)
value: 15
device: Device/astral
component
code: therapy-mode (ResMed Observation Metrics CodeSystem#therapy-mode)
value: Spont (ResMed therapy mode CodeSystem#SPONT)
component
code: active-program (ResMed Observation Metrics CodeSystem#active-program)
value: Program 1 (ResMed Therapy Program CodeSystem#1)
component
code: program-name (ResMed Observation Metrics CodeSystem#program-name)
value: Mouthpiece (ResMed Therapy Program Name CodeSystem#PN10)
Generated Narrative: Observation #astral-apnea-breathtype
status: PRELIMINARY
code: apnea-breath-type (ResMed Observation Metrics CodeSystem#apnea-breath-type)
value: No spont breath (ResMed settings values for spont breath#NOSPONTBREATH)
device: Device/astral
Generated Narrative: Observation #astral-apnea-interval
status: PRELIMINARY
code: apnea-interval (ResMed Observation Metrics CodeSystem#apnea-interval)
value: 262
device: Device/astral
Generated Narrative: Observation #astral-apnea-response
status: PRELIMINARY
code: apnea-response-type (ResMed Observation Metrics CodeSystem#apnea-response-type)
value: PACV alarm (ResMed settings values for apnea response#PACVALARM)
device: Device/astral
Generated Narrative: Observation #astral-apneavent-freq
status: PRELIMINARY
code: set-frequency-apnea-vent (ResMed Respiratory Setting CodeSystem#set-frequency-apnea-vent)
value: 30
device: Device/astral
Generated Narrative: Observation #astral-apneavent-peakinspflow
status: PRELIMINARY
code: set-peak-inspiratory-flow-apnea-vent (ResMed Respiratory Setting CodeSystem#set-peak-inspiratory-flow-apnea-vent)
value: 73
device: Device/astral
Generated Narrative: Observation #astral-apneavent-pressassist
status: PRELIMINARY
code: set-pressure-assist-apnea-vent (ResMed Respiratory Setting CodeSystem#set-pressure-assist-apnea-vent)
value: 20.6
device: Device/astral
Generated Narrative: Observation #astral-apneavent-ti
status: PRELIMINARY
code: set-inspiratory-time-apnea-vent (ResMed Respiratory Setting CodeSystem#set-inspiratory-time-apnea-vent)
value: 1.3
device: Device/astral
Generated Narrative: Observation #astral-apneavent-tidvolume
status: PRELIMINARY
code: set-tidal-volume-apnea-vent (ResMed Respiratory Setting CodeSystem#set-tidal-volume-apnea-vent)
value: 1.045
device: Device/astral
Generated Narrative: Observation #astral-autoepap
status: PRELIMINARY
code: auto-expiratory-pressure-state (ResMed Respiratory Setting CodeSystem#auto-expiratory-pressure-state)
value: Off (ResMed settings values for enable/disable options#OFF)
device: Device/astral
Generated Narrative: Observation #astral-circuit
status: PRELIMINARY
code: patient-circuit-type (ResMed Observation Metrics CodeSystem#patient-circuit-type)
value: Single circuit with leak (vented) (ResMed Ventilator Circuit CodeSystem#single-with-leak)
device: Device/astral
Generated Narrative: Observation #astral-cyclethresh
status: PRELIMINARY
code: cycle-threshold (ResMed Observation Metrics CodeSystem#cycle-threshold)
value: 50
device: Device/astral
Generated Narrative: Observation #astral-epap
status: PRELIMINARY
code: target-expiratory-pressure (ResMed Observation Metrics CodeSystem#target-expiratory-pressure)
value: 15
device: Device/astral
Generated Narrative: Observation #astral-heightcm
status: PRELIMINARY
code: patient-height (ResMed Observation Metrics CodeSystem#patient-height)
value: 200 cm (Details: UCUM code cm = 'cm')
device: Device/astral
Generated Narrative: Observation #astral-interface
status: PRELIMINARY
code: patient-interface (ResMed Observation Metrics CodeSystem#patient-interface)
value: Mask (ResMed settings values for interface type#MASK)
device: Device/astral
Generated Narrative: Observation #astral-mask
status: PRELIMINARY
code: mask-type (ResMed Observation Metrics CodeSystem#mask-type)
value: InLineVent (ResMed settings values for mask type#INLINEVENT)
device: Device/astral
Generated Narrative: Observation #astral-maxepap
status: PRELIMINARY
code: max-expiratory-pressure (ResMed Observation Metrics CodeSystem#max-expiratory-pressure)
value: 22.2
device: Device/astral
Generated Narrative: Observation #astral-minepap
status: PRELIMINARY
code: min-expiratory-pressure (ResMed Observation Metrics CodeSystem#min-expiratory-pressure)
value: 20.8
device: Device/astral
Generated Narrative: Observation #astral-patienttype
status: PRELIMINARY
code: patient-type (ResMed Observation Metrics CodeSystem#patient-type)
value: Adult (ResMed settings values for patient type#ADULT)
device: Device/astral
Generated Narrative: Observation #astral-risetime
status: PRELIMINARY
code: rise-time (ResMed Observation Metrics CodeSystem#rise-time)
value: 0.5
device: Device/astral
Generated Narrative: Observation #astral-targetalveolarvent
status: PRELIMINARY
code: target-alveolar-ventilation (ResMed Observation Metrics CodeSystem#target-alveolar-ventilation)
value: 10
device: Device/astral
Generated Narrative: Observation #astral-targetrate
status: PRELIMINARY
code: target-respiratory-rate (ResMed Observation Metrics CodeSystem#target-respiratory-rate)
value: 15
device: Device/astral
Generated Narrative: Observation #astral-timax
status: PRELIMINARY
code: set-max-inspiratory-time (ResMed Observation Metrics CodeSystem#set-max-inspiratory-time)
value: 2
device: Device/astral
Generated Narrative: Observation #astral-timin
status: PRELIMINARY
code: set-min-inspiratory-time (ResMed Observation Metrics CodeSystem#set-min-inspiratory-time)
value: 3
device: Device/astral
Generated Narrative: Observation #astral-trigger
status: PRELIMINARY
code: trigger-type (ResMed Observation Metrics CodeSystem#trigger-type)
value: OFF (ResMed settings values for levels#OFF)
device: Device/astral
Generated Narrative: Observation #astral-ivaps-maxps
status: PRELIMINARY
code: max-pressure-support (ResMed Observation Metrics CodeSystem#max-pressure-support)
value: 25
device: Device/astral
Generated Narrative: Observation #astral-ivaps-minps
status: PRELIMINARY
code: min-pressure-support (ResMed Observation Metrics CodeSystem#min-pressure-support)
value: 15
device: Device/astral